Know what’s in your water before anyone recommends equipment.
The Greeneville Water Commission reports that Greeneville’s water met or exceeded all state and federal drinking water standards in 2025, with no violations[1]. In plain English, the Greeneville Water Commission water quality report shows Nolichucky River water with chlorine at the tap, lead not detected at the 90th percentile, chlorination byproducts below federal limits and no PFAS found in EPA testing. Here’s what each number means for your home.
By sending this form, you agree that we may call or email you about your request. Texts are sent only if you check the box above.
The Greeneville Water Commission’s water is surface water from the Nolichucky River[1]. The state rates the Greeneville sources as reasonably susceptible to potential contamination. TDEC bases these ratings on geologic factors and human activities near the source[1]. The Commission’s board meets the last Tuesday of every month at 8:30 a.m. at the Commission office[1].
| What Greeneville measured | 2025 result | What it means at home |
|---|---|---|
| Chlorine | 2.24 ppm; range 0.09–3.3 ppm[1] | Still in the water at your tap. The limit is 4 ppm |
| Trihalomethanes | Running average 31 ppb; range 6.5–68 ppb[1] | Byproducts of chlorination; federal limit 80 ppb |
| Haloacetic acids | Running average 16 ppb; range 4–27 ppb[1] | Byproducts of chlorination; federal limit 60 ppb |
| Lead | 90th percentile not detected; range not detected to 8.8 ppb; 0 of 30 homes above the action level (2023)[1] | The action level is 15 ppb |
| Copper | 90th percentile 0.0332 ppm; 0 of 30 homes above the action level (2023)[1] | The action level is 1.3 ppm |
| Fluoride | 0.71 ppm; range 0.57–0.71 ppm[1] | The limit is 4 ppm |
| Sodium | 6.13 ppm[1] | No federal limit |
| Alpha emitters | 1.61 pCi/L; range 1.32–1.61[1] | The limit is 15 pCi/L |
| Turbidity | Highest 0.11 NTU; 100% of monthly samples below 0.3 NTU[1] | A sign the filters are working |
| PFAS and lithium (UCMR 5) | None found at or above EPA reporting levels[2] | Four samples in 2023 |
The Greeneville Water Commission says its water met or exceeded all state and federal standards during 2025 and that its system had no violations[1]. It reports no positive total coliform samples out of 480[1]. Two things are still worth knowing. The chlorine that protects the water on the way to you is still in it at the tap: the report lists 2.24 ppm, with readings from 0.09 to 3.3 ppm[1]. And what you drink also depends on the plumbing in your home, which the report says the Commission can’t control[1].
Chlorine reacts with natural organic matter in river water to form trihalomethanes and haloacetic acids. The Greeneville Water Commission reported a running average of 31 ppb for trihalomethanes, against a federal limit of 80 ppb, and 16 ppb for haloacetic acids, against a limit of 60 ppb[1]. If the taste or smell of chlorine bothers you, a carbon filter at the sink or whole-house water filtration are the usual options.
The Commission tests taps inside homes. In its most recent round, in 2023, lead was not detected at the 90th percentile, the highest result was 8.8 ppb, and none of the 30 homes sampled was above the 15 ppb action level for lead or for copper[1]. Its lead service line inventory is complete and posted at gwctn.org[1]. The report recommends cold water for drinking and cooking, flushing pipes that have sat, and a filter certified to reduce lead; lead testing questions go to (423) 638-3148[1]. Reverse osmosis at the kitchen tap is one common way to filter drinking water.
The Greeneville Water Commission’s report doesn’t discuss PFAS. EPA’s final UCMR 5 data, which list the system as “Greeneville Water & Light Comm”, cover it: four samples in February, May, August and November 2023 at the entry point EPA labels “Entry Point to Dist. System” at the Nolichucky River Plant found no PFAS and no lithium at or above EPA’s reporting levels[2]. The reporting level for PFOA and PFOS is 4 ppt[2]. For context, EPA’s limit for PFOA and for PFOS is 4 ppt, measured as a running annual average at each sampling point, with compliance due in 2029; a rule EPA proposed in May 2026 would let systems ask for an extension to 2031[3].
The Greeneville Water Commission’s report doesn’t publish a hardness number[1], so measure it at your tap before choosing a water softener. Homes outside the Commission’s lines may be on another utility or a private well, which no utility tests. EPA advises testing a well every year for total coliform bacteria, nitrates, total dissolved solids and pH[4]. See well water treatment, the other water quality guides and all areas we serve.
The Greeneville Water Commission reports that its water met or exceeded all state and federal standards in 2025, with no violations and no positive coliform samples out of 480. Lead was not detected at the 90th percentile. Chlorine was listed at 2.24 ppm. Your plumbing also matters, and a free in-home test shows your own tap.
The Greeneville Water Commission’s water is surface water from the Nolichucky River. The state rates its sources as reasonably susceptible to potential contamination.
EPA’s final UCMR 5 data show no PFAS and no lithium at or above reporting levels in four 2023 samples at the Greeneville system’s Nolichucky River Plant entry point. The reporting level for PFOA and PFOS is 4 ppt. The Commission’s own 2025 report doesn’t discuss PFAS.
The Greeneville Water Commission’s water quality report doesn’t publish a hardness number. Measure it at your own tap before deciding whether a softener is worth considering. A free in-home water test gives you the figure.
The Commission posts its Water Quality Report on the Reports page at gwctn.org. The newest edition covers 2025. For questions about the report, it lists the Greeneville Filtration Plant at (423) 798-2045.
Perfected Water. Purified Air. Peace of Mind. It starts with a free in-home test.
See our Bristol office on Google · Review our Bristol office on Google
Book a free in-home water test
All sources opened November 2026.




























By sending this form, you agree that we may call or email you about your request. Texts are sent only if you check the box above.