Know what’s in your water before anyone recommends equipment.
Northeast Knox Utility District (NEKUD) reports that it met state and federal drinking water standards, in its 2026 report covering 2025[1]. In plain English, the report shows Holston River water with chlorine at the tap, chlorination byproducts under federal limits on the running average, and low lead and copper. EPA’s PFAS testing of NEKUD’s water found none at or above its reporting levels[3]. Here’s what each number means for your home in northeast Knox County.
By sending this form, you agree that we may call or email you about your request. Texts are sent only if you check the box above.
NEKUD sits on the north side of the Holston River, northeast of the Knoxville city limits, with its office on Washington Pike in Corryton[2]. It has drawn water from the Holston River since it went into service in 1959, and today covers a service area of 65 square miles[2]. Its plant uses conventional treatment and can produce 6,912,000 gallons a day. It serves customers in northeast Knox County and also supplies Luttrell-Blaine-Corryton Utility District and the City of Maynardville[1]. TDEC rates the river source “reasonably susceptible” to potential contamination, a rating about the untreated water[1]. NEKUD reports a score of 99.0 on its most recent TDEC sanitary survey, in June 2024[1].
| What NEKUD measured | Result | What it means at home |
|---|---|---|
| Chlorine | Annual average 1.38 ppm; range 0.60–2.4[1] | Still in the water at your tap, shower and laundry; the limit is 4 ppm |
| Trihalomethanes | Highest locational running average 65.9 ppb; single results 30.1–103.0[1] | Chlorination byproducts; federal limit 80 ppb |
| Haloacetic acids | Highest locational running average 29.2 ppb; single results 13.9–52.6[1] | Chlorination byproducts; federal limit 60 ppb |
| Lead | 90th percentile 1.00 ppb; range below detection to 7.73 (2023)[1] | Low; the action level is 15 ppb |
| Copper | 90th percentile 0.0976 ppm (2023)[1] | Low; the action level is 1.3 ppm |
| Fluoride | Annual average 0.56 ppm; range 0.51–0.60[1] | Federal limit 4 ppm |
| Nitrate | 0.505 ppm[1] | Far below the 10 ppm limit |
| Sodium | 10.8 ppm[1] | Low |
| Turbidity | Annual average 0.050 NTU over 1,680 samples; 100% below 0.30 NTU[1] | A measure of how well the plant filters |
| Total organic carbon | Annual average 1.18 ppm; 32.5% removal where 25% is required[1] | Natural organic matter that chlorine can react with |
| Coliform bacteria | 360 samples in 2025; 0 total coliform violations[1] | Routine bacteria monitoring in the pipes |
| PFAS (EPA testing) | None at or above EPA reporting levels in four sampling rounds, Dec 2023–Sep 2024[3] | See the PFAS section below |
The regulatory answer is yes. NEKUD reports that it met state and federal drinking water standards, and every row in its 2025 table shows “N” in the violation column[1]. The fuller answer has three parts. First, the chlorine that protects the water on its way to you is still in it when it arrives. Second, chlorine forms byproducts, and NEKUD’s trihalomethane average is the number in its report closest to its limit. Third, NEKUD says it cannot control the materials used in your home’s plumbing[1], and those can change what comes out of the tap.
Trihalomethanes form when chlorine meets natural organic matter in river water. NEKUD reports them as a locational running annual average (LRAA), a running annual average at each sampling location[1]. Its highest was 65.9 ppb against the 80 ppb limit[1]. Single results ranged from 30.1 to 103.0 ppb. NEKUD’s table lists the highest LRAA against the 80 ppb limit and shows “N” in the violation column[1]. Haloacetic acids were lower, with a highest running average of 29.2 ppb against a 60 ppb limit[1]. If chlorine taste or smell bothers you, carbon filtration reduces it, either at one tap or with whole-house water filtration that also covers showers and laundry.
NEKUD’s report says lead and copper samples are required every three years, and it took 30 samples from points across its distribution system[1]. In the latest round, July to August 2023, the 90th percentile for lead was 1.00 ppb, the highest result was 7.73 ppb, and none of the 30 sites was above the action level[1]. NEKUD’s report explains that lead mainly comes from service lines and home plumbing, recommends cold water and flushing, and says a filter certified to reduce lead is effective[1]. Reverse osmosis at the kitchen tap is one common way to do that. NEKUD’s lead line inventory is on nekud.com[1].
NEKUD’s 2026 report doesn’t list a hardness figure[1], so we won’t guess one. It does list sodium at 10.8 ppm and, from 2020 sampling, sulfate at 11.1 ppm[1]. If you see spots, soap scum or scale, a free in-home water test measures hardness at your own tap, and a water softener sized to that number is the usual answer when it’s high enough to matter.
EPA’s UCMR 5 program sampled NEKUD’s water in four rounds between December 2023 and September 2024, at the entry point EPA labels “Entry Point A” at the Holston River Plant[3]. None of the 29 PFAS EPA tested for, including PFOA and PFOS, was found at or above EPA’s reporting levels; for PFOA and PFOS that level is 4 ppt[3]. EPA’s limit for PFOA and for PFOS is 4 ppt, measured as a running annual average, with compliance due in 2029; a rule EPA proposed in May 2026 would let systems ask for an extension to 2031[4].
If your water comes from another utility, that utility’s own report applies. KUB is explained in our Knoxville water report guide, and other districts and private wells are covered on our Knoxville page. For questions about NEKUD’s report, the number in the report is 865-687-5345[1].
NEKUD reports that it met state and federal drinking water standards in 2025, with no violations in its table. That’s the regulatory answer. The water still reaches your tap with chlorine, at an annual average of 1.38 ppm, and chlorination byproducts, and your home’s plumbing can affect what comes out of the faucet. A free in-home test shows your own tap.
NEKUD treats surface water from the Holston River at its own plant, which can produce 6,912,000 gallons a day. It serves northeast Knox County and also supplies Luttrell-Blaine-Corryton Utility District and the City of Maynardville.
Trihalomethanes are byproducts that form when chlorine reacts with natural organic matter. NEKUD’s highest locational running annual average in 2025 was 65.9 ppb, under the 80 ppb federal limit, with single results from 30.1 to 103.0 ppb. If chlorine taste or smell bothers you, carbon filtration is a common option.
In EPA’s UCMR 5 testing, four rounds of samples at NEKUD’s Holston River Plant between December 2023 and September 2024 showed none of the 29 PFAS tested at or above EPA’s reporting levels, including PFOA and PFOS, whose reporting level is 4 ppt.
In NEKUD’s latest lead and copper sampling, in 2023, the 90th percentile for lead was 1.00 ppb and none of the 30 sites sampled was above the 15 ppb action level. Lead mostly comes from home plumbing, so a certified filter is the usual step if you’re concerned.
Perfected Water. Purified Air. Peace of Mind. It starts with a free in-home test.
Call (865) 269-9007 for a free water test · Book a free in-home water test
Book a free in-home water test
All sources opened November 2026.




























By sending this form, you agree that we may call or email you about your request. Texts are sent only if you check the box above.